Ajout dela structure MDT dans Infra-LAB
This commit is contained in:
@@ -0,0 +1,353 @@
|
||||
<job id="ZTISCCM">
|
||||
<script language="VBScript">
|
||||
|
||||
' Due to an issue that may exist in x64 images captured by MDT 2010 Lite Touch,
|
||||
' there may be a need to clean up a bad registry key that would cause this script
|
||||
' to get into an infinite loop. This logic will fix that bad registry key
|
||||
' when necessary.
|
||||
|
||||
Dim tmpShell, tmpFSO
|
||||
Set tmpShell = CreateObject("WScript.Shell")
|
||||
Set tmpFSO = CreateObject("Scripting.FileSystemObject")
|
||||
If tmpFSO.FileExists(tmpShell.ExpandEnvironmentStrings("%WINDIR%\SysWOW64\CCM\TSCore.DLL")) then
|
||||
On Error Resume Next
|
||||
tmpShell.RegWrite "HKCR\TypeLib\{D5E1749D-832D-4587-AFC3-9462187FE2F5}\1.0\0\win64\", tmpShell.ExpandEnvironmentStrings("%WINDIR%\SysWOW64\CCM\TSCore.DLL")
|
||||
On Error Goto 0
|
||||
End if
|
||||
|
||||
</script>
|
||||
<script language="VBScript" src="ZTIUtility.vbs"/>
|
||||
<script language="VBScript">
|
||||
|
||||
' // ***************************************************************************
|
||||
' //
|
||||
' // Copyright (c) Microsoft Corporation. All rights reserved.
|
||||
' //
|
||||
' // Microsoft Deployment Toolkit Solution Accelerator
|
||||
' //
|
||||
' // File: ZTISCCM.wsf
|
||||
' //
|
||||
' // Version: 6.3.8456.1000
|
||||
' //
|
||||
' // Purpose: Initialize the Zero Touch deployment process in SCCM
|
||||
' //
|
||||
' // Usage: cscript ZTISCCM.wsf [/debug:true]
|
||||
' //
|
||||
' // ***************************************************************************
|
||||
|
||||
Option Explicit
|
||||
RunNewInstance
|
||||
|
||||
'//----------------------------------------------------------------------------
|
||||
'//
|
||||
'// Global constants
|
||||
'//
|
||||
'//----------------------------------------------------------------------------
|
||||
|
||||
|
||||
|
||||
'//----------------------------------------------------------------------------
|
||||
'// Main Class
|
||||
'//----------------------------------------------------------------------------
|
||||
|
||||
Class ZTISCCM
|
||||
|
||||
'//----------------------------------------------------------------------------
|
||||
'// Class instance variable declarations
|
||||
'//----------------------------------------------------------------------------
|
||||
|
||||
'//----------------------------------------------------------------------------
|
||||
'// Constructor to initialize needed global objects
|
||||
'//----------------------------------------------------------------------------
|
||||
|
||||
Private Sub Class_Initialize
|
||||
|
||||
|
||||
End Sub
|
||||
|
||||
'//----------------------------------------------------------------------------
|
||||
'// Main routine
|
||||
'//----------------------------------------------------------------------------
|
||||
|
||||
|
||||
Function Main
|
||||
|
||||
Dim iRetVal
|
||||
Dim oDebug
|
||||
Dim sCmd
|
||||
Dim sBootstrap, sTSPath, sFile, sParms
|
||||
Dim oDrive
|
||||
Dim bTSInProgress
|
||||
Dim oAccount
|
||||
Dim sBddrun
|
||||
Dim sArchiveDir
|
||||
Dim sArchitecture
|
||||
|
||||
|
||||
iRetVal = Success
|
||||
|
||||
|
||||
'//----------------------------------------------------------------------------
|
||||
'// If debugging, create flag files
|
||||
'//----------------------------------------------------------------------------
|
||||
|
||||
If oLogging.Debug then
|
||||
|
||||
On Error Resume Next
|
||||
|
||||
Set oDebug = oFSO.OpenTextFile(Left(oUtility.LogPath, 2) & "\OSD.Debug", ForAppending, True)
|
||||
oDebug.WriteLine "OSD.Debug"
|
||||
oDebug.Close
|
||||
|
||||
Set oDebug = oFSO.OpenTextFile(Left(oUtility.LogPath, 2) & "\MININT\Archive_OSD.sms", ForAppending, True)
|
||||
oDebug.WriteLine "Archive_OSD.sms"
|
||||
oDebug.Close
|
||||
|
||||
On Error Goto 0
|
||||
|
||||
End if
|
||||
|
||||
' Clean up MININT folder if it exists
|
||||
For each oDrive in oFSO.Drives
|
||||
If oDrive.DriveType = 2 and oDrive.DriveLetter<>"X" then
|
||||
If oDrive.IsReady Then
|
||||
If OFSO.FolderExists(ODrive.DriveLetter & ":\MININT") then
|
||||
On Error Resume Next
|
||||
oFSO.DeleteFolder oDrive.DriveLetter & ":\MININT", true
|
||||
On Error Goto 0
|
||||
|
||||
Exit For
|
||||
End if
|
||||
End If
|
||||
End if
|
||||
Next
|
||||
|
||||
|
||||
|
||||
'//----------------------------------------------------------------------------
|
||||
'// Set the DeployRoot and ScriptRoot based on where we were started from
|
||||
'//----------------------------------------------------------------------------
|
||||
|
||||
' Figure out the architecture from the environment
|
||||
|
||||
If oEnv("PROCESSOR_ARCHITEW6432") <> "" then
|
||||
If UCase(oEnv("PROCESSOR_ARCHITEW6432")) = "AMD64" then
|
||||
sArchitecture = "X64"
|
||||
Else
|
||||
sArchitecture = UCase(oEnv("PROCESSOR_ARCHITEW6432"))
|
||||
End if
|
||||
ElseIf UCase(oEnv("PROCESSOR_ARCHITECTURE")) = "AMD64" then
|
||||
sArchitecture = "X64"
|
||||
Else
|
||||
sArchitecture = UCase(oEnv("PROCESSOR_ARCHITECTURE"))
|
||||
End if
|
||||
|
||||
|
||||
oEnvironment.Item("ScriptRoot") = oFSO.GetParentFolderName(WScript.ScriptFullName)
|
||||
oLogging.CreateEntry "ScriptRoot = " & oEnvironment.Item("ScriptRoot"), LogTypeInfo
|
||||
|
||||
oEnvironment.Item("DeployRoot") = oFSO.GetParentFolderName(oEnvironment.Item("ScriptRoot"))
|
||||
oLogging.CreateEntry "DeployRoot = " & oEnvironment.Item("DeployRoot"), LogTypeInfo
|
||||
|
||||
oEnvironment.Item("ToolRoot") = oEnvironment.Item("DeployRoot") & "\Tools\" & sArchitecture
|
||||
oLogging.CreateEntry "ToolRoot = " & oEnvironment.Item("ToolRoot"), LogTypeInfo
|
||||
|
||||
oLogging.CreateEntry "DeployRoot = " & oEnvironment.Item("DeployRoot"), LogTypeInfo
|
||||
|
||||
oEnvironment.Item("ResourceRoot") = oEnvironment.Item("DeployRoot")
|
||||
oLogging.CreateEntry "ResourceRoot = " & oEnvironment.Item("ResourceRoot"), LogTypeInfo
|
||||
If Instr(oEnvironment.Item("DeployRoot"),":\") OR OEnvironment.GetOSDV4("_SMSTSMDATAPATH")<> "" Then
|
||||
|
||||
If oFSO.FolderExists(oEnvironment.GetOSDV4("_SMSTSMDataPath") & "\WDPackage") <> True Then
|
||||
|
||||
oFSO.Copyfolder oEnvironment.Item("DeployRoot"),oEnvironment.GetOSDV4("_SMSTSMDataPath") & "\WDPackage"
|
||||
|
||||
End if
|
||||
|
||||
oEnvironment.Item("ScriptRoot") = oEnvironment.GetOSDV4("_SMSTSMDataPath") & "\WDPackage\Scripts"
|
||||
oLogging.CreateEntry "ScriptRoot = " & oEnvironment.Item("ScriptRoot"), LogTypeInfo
|
||||
|
||||
oEnvironment.Item("DeployRoot") = oFSO.GetParentFolderName(oEnvironment.Item("ScriptRoot"))
|
||||
oLogging.CreateEntry "DeployRoot = " & oEnvironment.Item("DeployRoot"), LogTypeInfo
|
||||
|
||||
oEnvironment.Item("ToolRoot") = oEnvironment.Item("DeployRoot") & "\Tools\" & sArchitecture
|
||||
oLogging.CreateEntry "ToolRoot = " & oEnvironment.Item("ToolRoot"), LogTypeInfo
|
||||
|
||||
oEnvironment.Item("ResourceRoot") = oEnvironment.Item("DeployRoot")
|
||||
oLogging.CreateEntry "ResourceRoot = " & oEnvironment.Item("ResourceRoot"), LogTypeInfo
|
||||
|
||||
End if
|
||||
|
||||
' Set the package ID that we are running from (promote to global)
|
||||
|
||||
oEnvironment.Item("BDDPackageID") = oEnvironment.Item("BDDPackageID")
|
||||
oLogging.CreateEntry "BDDPackageID = " & oEnvironment.Item("BDDPackageID"), LogTypeInfo
|
||||
|
||||
|
||||
' Log the data path and logging path
|
||||
|
||||
oLogging.CreateEntry "LocalRootPath = " & oUtility.LocalRootPath, LogTypeInfo
|
||||
oLogging.CreateEntry "LogPath = " & oUtility.LogPath, LogTypeInfo
|
||||
|
||||
|
||||
'//----------------------------------------------------------------------------
|
||||
'// Gather information
|
||||
'//----------------------------------------------------------------------------
|
||||
|
||||
oEnvironment.Item("DeploymentMethod") = "SCCM"
|
||||
oLogging.CreateEntry "DeploymentMethod = " & oEnvironment.Item("DeploymentMethod"), LogTypeInfo
|
||||
|
||||
If oEnvironment.Item("DeploymentType") = "" then
|
||||
|
||||
If oEnv("SystemDrive") = "X:" then
|
||||
|
||||
oEnvironment.Item("DeploymentType") = "NEWCOMPUTER"
|
||||
|
||||
ElseIf oFSO.FileExists(oUtility.ScriptDir & "\OldComputer.tag") then
|
||||
|
||||
oEnvironment.Item("DeploymentType") = "REPLACE"
|
||||
|
||||
Else
|
||||
|
||||
oEnvironment.Item("DeploymentType") = "REFRESH"
|
||||
|
||||
End if
|
||||
|
||||
End if
|
||||
|
||||
|
||||
' Reset the Destination Logical Drive ( Drive letter may have changed after rebooting )
|
||||
|
||||
oUtility.ClearRelativeDriveLetters
|
||||
oUtility.GetOSTargetDriveLetterEx False
|
||||
|
||||
|
||||
oLogging.CreateEntry "DeploymentType = " & oEnvironment.Item("DeploymentType"), LogTypeInfo
|
||||
oLogging.CreateEntry "Phase = " & oEnvironment.Item("Phase"), LogTypeInfo
|
||||
|
||||
|
||||
' Set the start time in GMT if not already set
|
||||
|
||||
If oEnvironment.Item("OSDStartTime") = "" then
|
||||
|
||||
Dim timeBias
|
||||
Dim timeUTC
|
||||
Dim timeBranding
|
||||
|
||||
|
||||
' Get current time in UTC
|
||||
|
||||
timeBias = oShell.RegRead("HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\TimeZoneInformation\ActiveTimeBias")
|
||||
timeUTC = DateAdd("n", timeBias, Now())
|
||||
|
||||
|
||||
' Save the time
|
||||
|
||||
timeBranding = Year(timeUTC) & "-" & _
|
||||
Right( "0" & Month(timeUTC), 2) & "-" & _
|
||||
Right( "0" & Day(timeUTC), 2) & " " & _
|
||||
Right( "0" & Hour(timeUTC), 2) & ":" & _
|
||||
Right( "0" & Minute(timeUTC), 2) & ":" & _
|
||||
Right( "0" & Second(timeUTC), 2) & "Z"
|
||||
|
||||
oEnvironment.Item("OSDStartTime") = timeBranding
|
||||
|
||||
End if
|
||||
|
||||
|
||||
' Enable DaRT remote control (for Windows PE)
|
||||
|
||||
EnableDaRT
|
||||
|
||||
End Function
|
||||
|
||||
Sub EnableDaRT
|
||||
|
||||
Dim tries
|
||||
Dim oInv
|
||||
Dim oTicketNode
|
||||
Dim oIPNode
|
||||
Dim dicPortList
|
||||
Dim dicIPList
|
||||
|
||||
|
||||
' Remote control is only supported in Windows PE (don't use OSVersion as it isn't set yet for refresh)
|
||||
|
||||
If oEnv("SystemDrive") <> "X:" then
|
||||
Exit Sub
|
||||
End if
|
||||
|
||||
|
||||
' Don't start remote control if it has already been started
|
||||
|
||||
If oFSO.FileExists(oEnv("SystemRoot") & "\System32\inv32.xml") then
|
||||
Exit Sub
|
||||
End if
|
||||
|
||||
|
||||
' Initialize
|
||||
|
||||
Set dicIPList = CreateObject("Scripting.Dictionary")
|
||||
Set dicPortList = CreateObject("Scripting.Dictionary")
|
||||
|
||||
|
||||
' Make sure the executable exists
|
||||
|
||||
If not oFSO.FileExists(oEnv("SystemRoot") & "\System32\RemoteRecovery.exe") then
|
||||
Exit Sub
|
||||
End if
|
||||
|
||||
|
||||
' Start remote recovery process
|
||||
|
||||
oShell.CurrentDirectory = oEnv("SystemRoot") & "\System32"
|
||||
oShell.Run oEnv("SystemRoot") & "\System32\RemoteRecovery.exe -nomessage", 2, false
|
||||
|
||||
|
||||
' Sleep until we see the inv32.xml file
|
||||
|
||||
tries = 0
|
||||
Do
|
||||
WScript.Sleep 1000
|
||||
tries = tries + 1
|
||||
Loop While not oFSO.FileExists(oEnv("SystemRoot") & "\System32\inv32.xml") and tries < 10
|
||||
|
||||
If not oFSO.FileExists(oEnv("SystemRoot") & "\System32\inv32.xml") then
|
||||
oLogging.CreateEntry "Unable to find the inv32.xml file, DaRT remote control is not running.", LogTypeInfo
|
||||
Exit Sub
|
||||
End if
|
||||
|
||||
|
||||
' Read the XML file and put the values into variables
|
||||
|
||||
On Error Resume Next
|
||||
|
||||
Set oInv = oUtility.CreateXMLDOMObjectEx(oEnv("SystemRoot") & "\System32\inv32.xml")
|
||||
Set oTicketNode = oInv.SelectSingleNode("//A")
|
||||
oEnvironment.Item("DartTicket") = oTicketNode.Attributes.getNamedItem("ID").value
|
||||
|
||||
' First get the IPv4 entries (skipping locally-administered ones)
|
||||
For each oIPNode in oInv.SelectNodes("//L")
|
||||
If Instr(oIPNode.Attributes.getNamedItem("N").value, ":") = 0 and Left(oIPNode.Attributes.getNamedItem("N").value, 4) <> "169." then
|
||||
dicIPList.Add oIPNode.Attributes.getNamedItem("N").value, ""
|
||||
dicPortList.Add oIPNode.Attributes.getNamedItem("P").value, ""
|
||||
End if
|
||||
Next
|
||||
|
||||
' Then add the IPv6 entries
|
||||
For each oIPNode in oInv.SelectNodes("//L")
|
||||
If Instr(oIPNode.Attributes.getNamedItem("N").value, ":") > 0 then
|
||||
dicIPList.Add oIPNode.Attributes.getNamedItem("N").value, ""
|
||||
dicPortList.Add oIPNode.Attributes.getNamedItem("P").value, ""
|
||||
End if
|
||||
Next
|
||||
oEnvironment.ListItem("DartIP") = dicIPList
|
||||
oEnvironment.ListItem("DartPort") = dicPortList
|
||||
|
||||
End Sub
|
||||
|
||||
|
||||
End Class
|
||||
|
||||
</script>
|
||||
</job>
|
||||
Reference in New Issue